Abstract:
We investigate the effects of key parameters of the rock bed system on thermal cooling performance of the system
after a fixed time of operation. The method of solving the mathematical model uses a semi-discretization finite difference
approximation for discretizing space in solid problem domain. A finite element approximation is used in the fluid problem
domain. Graphical results on the effects of parameter variation on damping and time delay on the peaking of the outlet air
temperature through the bed are presented and discussed.